  • This was occurring for me also since 9/20. I deleted all cookies on chatgpt, reloaded the site, and logged back in. It would work for 20 to 30 minutes then do it again. Each time, the browser console would have a ton of 503 errors.

    It seems that some of their nodes are working and some are in failure state. Their load balancer is occasionally directing to failed nodes.




  • If you’re getting water inside, Jchannel is probably the least of your concerns. Something isn’t sealed correctly. Unfortunately, if you have water getting in, you have water in your wall. Even if you seal the window, you could end up with a mold issue.

    If it was me, I’d pull the window, ensure all flashing and housewrap is in place, the reseat the window in a thick bead of silicone. Assuming the window is still in good shape. Otherwise, a new window is needed. Once the window is in place, trim, jchannel, and siding would be put back.

    Once the window is properly installed, I’d focus on the inside. Pull the trim and drywall around the window, letting it air out for a day then coat the inside sheeting with mold killing primer. New insulation would be added before new drywall is put in. Then mud, sand, paint, and reinstall the trim.

    It’s a decent amount of work, but not insurmountable. My concern is, if it was installed incorrectly, chances are, your other windows were too. I’m not trying to be doom and gloom here, just trying to forewarn you. It’s something to keep an eye on.

    All of this is assuming the problem isn’t something like a window left open or something like that.



  • darkmarx@lemmy.worldtoDIY@slrpnk.netDrawer Slides
    link
    fedilink
    English
    arrow-up
    16
    ·
    edit-2
    3 months ago

    The silver things are runners with ball bearings that drawer slides on. The slides that attach to the drawer will snap into these silver runners.

    Usually, you just need to align the slides on the drawer with the runners and push. They should snap in. The runners tend to slide around while connecting them. If they slide to the back, it’s ok, they will still connect once you get them lined up and push the drawer into them. If you can reach from underneath, you can hold the runner in place while attaching the drawer. Do one side at a time.

    If you’re struggling to get it to connect, I recommend removing the slide from the side of the drawer and seeing if you can get a single slide to attach to the runner. It will click when it attaches. By doing just one, you might have an easier time seeing how it connects.

    Once you figure it out, you’ll need to disconnect it. There should be a little plastic lever that you hold down (or up, depending on the side) while you pull out the slide. Put it back on the drawer and see if you can connect it once it’s back on the drawer.

    They are a little complicated, but once you see how it goes together, it should make sense. If what I said is still confusing or if you are still struggling, reply and I’ll see if I can get some pictures to explain it better.

    • Edit: A common mistake I’ve seen is putting the slides on the drawer backwards. The part attached to the drawer should have the flat part against the drawer. The drawer should look like this ]|_______|[

  • I get why people are upset by the headline. It is written to provoke anger. Unfortunately, anger at the wrong issue.

    I understand the argument that a large company can absorb the cost of workers they don’t currently. Though it’s unrealistic to expect them too.

    I lived in the Quad Cities for a number of years. A large majority of people I know, both family and friends, worked for either Deere or Case IH - until they closed the plant in East Moline.

    Layoffs are a yearly thing. Deere, Case, Caterpillar, they all hire a bunch of people in the beginning of the year and lay them off towards the end. It’s typically around August or September, and they announce it in July. Everyone in the Quad Cities knows it. It is expected. Sometime early next year, they are going to hire these jobs back. The people who take these jobs go into it knowing this is going to happen.

    It can suck being let go and some people might struggle with it. Those who are used to this cycle treat it as a well-paying seasonal job. Many already have something else lined up. This is only a single, anecdotal, data point, so take it with a grain of salt… one of my uncles works for Deere and is a bus driver for one of the school districts. He knows Deere is going to let him go by fall so he has the driving job for the rest of the year. In spring, he will go back to Deere.

    Perspective is also important. Deere has somewhere between 80k and 85k employees. They are laying off < 1000 based on this story. That’s the equivalent of a small, 80 person company hiring 1 person to get through the holiday season, then laying them off in January. Next year, they will do it again.

    Headlines like this are nothing more than a distraction from real issues. For example, why does any company have multi-billions of dollars in profit to begin with? It just means they are charging more than they need to. The farmers who buy Deere equipment then have to charge more for their produce. Which means the stores have to charge more. Which means we pay more for our food. Deere’s profits are leading to higher food prices for everyone. To me, that is more of an issue than 1/80th of their workforce being in a hire/layoff cycle.




  • AC as refrigerant, not coolant. Although that might be semantics.

    AC is a type of heat pump. You are moving heat from inside to outside. The physics behind a heat pump, is fairly simple. There are three principles to work with.

    1. Take a gas, compress it, and it gets super hot.
    2. Take a compressed gas, let it rapidly expand, and it gets super cold
    3. Different temperature gases move from hot to cold

    Let’s focus on AC since most folks are used to that concept. In an AC, you have a closed loop of refrigerant. Outside, there is a compressor that compresses the gas, which makes it very hot. The gas is pushed through a radiator with a fan pulling air through it. Since hot moves to cold, the heat trapped in the gas moves to the outside air, and the gas is slightly cooled. (As long as the gas is hotter than outside).

    Inside, there is an expansion valve that lets the gas rapdly expand, making it super cold. It is pumped through a radiator that has inside air blowing over it with a fan. Since hot moves to cold, the heat in the inside air moves to the cold gas, cooling the inside air. (As long as the gas is cooler than the inside temperature). It is then pumped outside to start the loop again.

    So, inside gets cooler while the heat is moved outside. The physics also establishes the limits of the heat exchange. You will only grab heat from inside if the expansion makes the gas colder than the air inside. Typically it expands to around 0 degrees. Likewise, it will dump the heat outside if the gas is hotter than outside air. The compressor typically makes it 130 to 140 degrees (temps vary depending on many factors).

    To use a heat pump for heating rather than cooling, reverse the process. Pick up the heat from outside and dump it inside. This will work as long as outside is warmer than the expanded gas (0 degrees or so). Although you can get some that go to around -20.